Modbus EFM EIE

The Modbus EFM EIE supports connectivity to Modbus RTU devices using the standard Gould/Modicon Modbus protocol as well as Enron extensions for single- and multi-register read/writes of 32-bit integer/floating-point and string values. Modbus RTU, TCP, and ASCII protocols are supported. The protocol selection is a property of the remote device. In addition to support for common Modbus data groups, the Modbus EFM EIE also supports Enron events and history, and FMS data groups.

Modbus EFM EIE data groups are highly configurable and depend on you to define each to suit your unique needs. This enables you to create and alter interface templates for a range of Modbus devices, which vary widely in their configuration requirements. FMS data groups depend on other data groups to be defined in order for FMS transactions to be completed. The "Composite Data Group" is supported by this EIE.

Custom Modbus data groups can be added and deleted. Enron data groups must contain the correct number and types of data group elements per the Enron EFM standard. For applicable data group elements, units must be defined in the template. See your field device's manufacturer documentation for supported unit types. UDCs can be mapped to data group elements.

Specifications

The following table lists and describes EIE specifications.

Manufacturer

Various

Protocol(s)

Modbus RTU

Modbus TCP/IP

Model(s)

Omni Flow Computer

UNICO LRP 250

UNICO RPC v100

UNICO RPC v110

UNICO RPC v200

Weatherford CEO-III

Weatherford CEO-IV

Weatherford CF-105 (a.k.a. Stealth)

Weatherford F-22

Required Files

CxDdsModbusEfmEditors.dll

UisModbusEfmDeviceDriver.dll or UisModbusEfmDeviceDriver64.dll

Sample Templates

ModbusEfm_CEOIII.dtf

ModbusEfm_Def.dtf

ModbusEfm_FmsLiquid.dtf

ModbusEfm_SampleBarton.dtf

ModbusEfm_SampleFlowAuto.dtf

ModbusEfm_UnicoLRP.dtf

ModbusEfm_WellPilot_CF105.dtf

ModbusEfm_WellPilot_F22.dtf

ModbusEfm_WFTA1K.dtf

Additional sample templates are available upon request.

eieType

ModbusEfm

Cryout Support

No

FMS Support

Yes, using FMS EFM data items.

Note: In cases where both GMR and FMS support was previously available, CygNet Measurement now provides data support using FMS data items only. If you were previously using GMR data items, you must update to use FMS data items. Update options are provided as part of your software upgrade procedure.

Listen Mode

Yes

64-bit Support

Yes. See 64-bit Device Drivers.

For more information, see sample device template files and manufacturer documentation.